Architectural

BUILDING HEIGHT  
Floor to Floor Typical floor, 4.00 m, Ground floor 6.3 m
Floor to Ceiling Ground floor 5.95 m (Floor to soffit of slab)
Elevators 5 nos x 20 passengers with speed of 1.5m/sec + one service elevator
Atrium Height 10.97 m
Other Features

Atrium for leisure activities and Retail Outlets/ ATMs Landscaped Courtyards

 

 

 

 

 

Finishes

External Cladding Double glass structural glazing for better noise control Granite cladding/Sandstone
Alucobond cladding
Roof Finish

Inverted construction with rigid insulation and waterproof Membrane

Flooring Atrium: Granite/ Marble
Entrance & Lift lobbies: Granite
Basement: Concrete with non-metallic floor hardener
Tenant floor finish: 75mm clearance left
Passenger Lift Cab: SS panels/ mirror, Granite flooring
Toilets: Floors & Walls in Vetrified tiles
Passenger Lift Cabs Cabs SS panels/ mirror, Granite flooring.
Atrium Lobby Granite cladding/ Veneer on walls with Reception/ Security Desk
Toilets  Floors & Walls in Vitrified tiles

 

 

 

 

 

Parking

Parking Spaces

Basement parking: 324 cars + Parking at ground level: 71 cars

Control barriers with swipe card readers

   
   
   
   
   

 

 

 

 

 

Landscaping

Roadways & Surface Concrete paving in main drive way and drop off in flamed granite. Grasscrete and interlocked concrete precast pavers in other areas.
Pedestrian and Roadway Lighting Pole and bollard mounted fixtures
Building Facade Lighting Feature lighting of facade with fixtures concealed within Landscaped areas.
   
   
   

 

 

 

 

 

Fire Safety

Staircase One main staircase and one fire escape staircase in each block
Wet Riser/ Hose Reels  Adjacent to each staircase
Sprinklers Fully provided in all parts of the building as per National Building Code of India norms.
Hydrants Provided at ground level as per NEC norms.
   
   

 

 

 

 

 

Security

CCTV Cameras Main Entrance, Main lift lobby, Service entrance
Doors Magnetic contacts provided to all external doors
Control Point Central security disk in atrium
   
   
   

 

 

 

 

 

 

Communications

General Provisions

Provision for satellite dish, shafts and trays
Telephone lines available for immediate connection
Provision for video conferencing

   
   
   
   
   

 

 

 

 

 

Structure

Floor Slab

Concrete flat slab to maximize clear spans (9.0m & 10.5m).

   
   
   
   
   

 

 

 

 

 

Mechanical

Air Conditioning Provision of VFD controlled chillers with standby unit for 100% reliability.
Air Handling Units Individual AHUs for each floor.
Provisions for VAV (Variable Air Volume) air distribution system.
Cooling Towers Provided with spare condenser water capacity for tenant's use if required.
BMS and Controls Hands free operation and monitoring the principle operations of the building control system fully integrated with the security, fire alarm and lift control systems.
Common Areas Air conditioned, with atrium link to restaurant and health club.
   

 

 

 

 

 

Electrical

Diesel Generators 100% fully automatic backup (30 second switch over) provided for lighting power and AC
Metering Metering split into common loads and tenant loads
Fire Alarm Systems Main alarm panels, break glass contacts, smoke and heat Detectors provided
Emergency Lighting Emergency light fixtures (on UPS) on escape route and at all means of egress
Metering Metering split into common loads and tenant loads.
Fire Alarm Systems Main alarm panels, break glass contacts, smoke and heat Detectors provided.
Emergency Lighting Emergency lighting has been provided for all Common areas, Staircases, Escape Routes and Lift Lobby.
 

 

 

 

 

 

 

Plumbing

Sanitary Fittings Vitreous chinaware, Mixer taps, automatic cistern sensors for urinals.
Accessories Full range of accessories.
   
   
   
   

 

 

 

 

 

 

Signage

General Provisions Brushed stainless steel custom-designed signage.